Vela – vent / Vela – star
-
Excellent thermal insulation properties.
-
Double seal for superior air tightness and rain resistance.
-
DESIGN: Vela-vent separate damper or Vela-vent_double damper.
-
USE: Smoke and heat extraction (SHEV) and natural ventilation. For Topline ELS and Proline strip skylights.
Document to download: Technical parameters_VELA.pdf
Leo – vent / Leo – star
-
Economic variant with variable use.
-
Drop tested.
-
DESIGN: Separate Leo-star or Leo-vent device integrated into the belt skylight. Leo-vent also available as a double flap. Optionally with the possibility of ventilation in bad weather with RPV (rain-proof-ventilation) technology.
-
USE: Ventilation and smoke and heat extraction (SHEV) in the roof and wall.
Download document: Technical parameters_LEO.pdf
Draco - vent / Draco - star
-
High-quality processing for demanding technical requirements.
-
Possibility of double or triple glazing.
-
Draco-vent available as a double wing. Optionally with the possibility of ventilation in bad weather with RPV (rain-proof-ventilation) technology.
-
Draco-vent: Integrated into the strip skylight for ventilation or as a device for natural smoke and heat extraction (SHEV).
-
Draco-star: Free-standing as a flat roof window, ventilation flap or smoke and heat exhaust (SHEV) flap, in individual construction sizes and mounting angles.
Download document: Technical parameters_DRACO.pdf
Lyra - vent / Lyra - star
-
Variable use as a device for ventilation and natural smoke and heat extraction (SHEV)
-
Design optionally with polycarbonate (Lyra_P) or aluminum (Lyra_A) slats
-
USE: Ventilation and smoke and heat extraction (SHEV) for installation in the roof or facade.
PROPERTIES
If the Lyra is used only as a device for ventilation purposes, it can be sized as desired.
BLINDS (LYRA_P) Dimensions (m): Aa (m2):
Pneumaticky CO2 0,88 – 2,31 x 1,15 – 2,91 0,66 – 4,03
Elektricky 24V 0,88 – 1,88 x 1,15 – 2,03 0,57 – 2,40
BLINDS (LYRA_vent_A) Dimensions (m): Aa (m2):
Pneumaticky CO2 0,84 – 2,24 x 0,62 – 2,39 –
Elektricky 24V 0,84 – 2,24 x 0,62 – 2,23 –
PRODUCT VARIANTS
TYPE
Lyra–star
Lyra-vent
USE
As a device for ventilation and air supply in production and storage halls
Lyra–vent_P:For all types of INDU LIGHT track lights
Lyra–vent_A:For INDU LIGHT Skyline, Shedline and Sideline track lights
EXECUTION
Separate device
Integrated
+ regulatory technology
+ professional maintenance
-
Comfortable ventilation and heat removal at the push of a button, with pneumatic (CO2) or electric (24/230V) control.
-
Professional installation, regular maintenance at statutory test intervals.
Download document: Technical parameters_LYRA.pdf
Virgo – vent / Virgo – star
-
Guaranteed ventilation in bad weather with RPV (rain-proof-ventilation) technology
-
Multi-purpose ventilation system with the option of any dimensions
-
Optionally as a device for natural smoke and heat extraction (SHEV) with CE certificate
-
USE:
-
Virgo-star: A freestanding device.
-
Virgo-vent: Integrated in all Indu-Light continuous skylights.
PRODUCT VARIANTS
TYPE
Virgo_Z
Virgo_I
APPEARANCE
View and design solution
A practical and industrial solution
PROPERTIES
Including thermally insulated base
Optionally with thermally insulated base
+ regulatory technology
+ professional maintenance
+ protection against insects
-
Comfortable ventilation and heat removal at the push of a button, with pneumatic (CO2) or electric (24/230V) control.
-
Professional installation, regular maintenance at statutory test intervals.
-
Easy-to-maintain insect protection for higher hygiene requirements, e.g. in the food industry
Download document: Technical parameters_VIRGO.pdf
Hydra - vent / Hydra - star
Permanent ventilation, independent of the weather, protected against rain
USE: Removal of permanent heat loads that arise in production and other operations with large heat gains.
The Hydra-star Indu-Light labyrinth device is an ideal system for natural ventilation and heat removal from rooms with higher temperatures.
HYDRA–STAR:
-
A system solution for draining falling rainwater using a three-level, partially overlapping, set of gutters on slats. Low weight of the device itself for minimal load on the roof (closable device weighs only 65 kg/m2, fixed labyrinths 57 kg/m2) With a maximum width of 4 m and essentially unlimited length of labyrinths, all customer requirements for venting technological heat can be met. The efficiency of the device is approx. Cv = 0.6.
Ways of placement on the roof sheathing:
As a standalone device on its own cuff
Integrated into existing or new rooflights
As a portable device for closing mounting holes.
+ regulatory technology
+ soundproof panels
-
Comfortable ventilation and heat removal at the push of a button, with pneumatic (CO2) or electric (24/230V) control.
-
Installation under the ventilation system
Download document: Technical parameters_HYDRA.pdf
Taurus – vent / Taurus – star
Permanent ventilation, independent of the weather, protected against rain
In the event of a fire, extraction of hot smoke from a defined section.
PRODUCT EXTENSIONS:
+ regulatory technology
+ soundproof panels
-
Comfortable ventilation and heat removal at the push of a button, with pneumatic (CO2) or electric (24/230V) control.
-
Installation under the ventilation system